Symptom
show platform resources cmd output show Control Processor Row values shown as - Warning=5 % and Critical=10%.
These values should be set to 90% and 95% respectively.
Cat9K#show platform resources
**State Acronym: H - Healthy, W - Warning, C - Critical
Resource Usage Max Warning Critical State
----------------------------------------------------------------------------------------------------
Control Processor 7.06% 100% 5% 10% W
DRAM 1103MB(56%) 1967MB 90% 95% H
Following logs may be seen as a consequence.
Jan 2 17:11:19.449: %PLATFORM-3-ELEMENT_CRITICAL: Switch 1 R0/0: smand: 3/RP/0: 5-Minute Load Average value 9.00 exceeds critical level 8.00
Jan 2 17:11:25.120: %PLATFORM-4-ELEMENT_WARNING: Switch 1 R0/0: smand: 6/RP/0: 5-Minute Load Average value 7.00 exceeds warning level 5.00
Further Problem Description
On the show platform resources cmd output ,show platform resources show Control Processor Row values are shown as - Warning=5 % and Critical=10%.
These values should be set to 90% and 95% respectively.