Symptom
No symptoms are seen previous the reload, but a hint that the switch was affected by this bug is seen on the show version output after the crash like this:
Hardware
cisco Nexus5548 Chassis ("O2 32X10GE/Modular Universal Platform Supervisor")
Intel(R) Xeon(R) CPU with 8253800 kB of memory.
Processor Board ID FOC1647580J
Device
bootflash 2007040 kB
Kernel uptime is 0 day(s), 0 hour(s), 19 minute(s), 26 second(s)
Last reset at 300355 usecs after
Reas Reset triggered due to HA policy of Reset
System version 7.3(1)N1(1)
Servi afm hap reset <<<<
plugin
Core Plugin, Ethernet Plugin
Conditions
Based on core file info, AFM process has not sent the heartbeat for longer time and during ASIC stats read call, hit crash.
Workaround
No Workarounds found for this issue