Symptom
On 16.12.20190910:040918
The command is missing randomly some AP names, so the information is incomplete and not usable
Example:
------------------ show ap dot11 5ghz cleanair air-quality summary ------------------
AQ = Air Quality
AP Name Channel Avg AQ Min AQ Interferers Spectrum AP Type
------------------------------------------------------------------------------
44 99 99 0 CA
48 99 99 0 CA
157 99 99 0 CA
161 99 99 0 CA
csg-bgl18-01a-cap08 36 99 99 0 CA
csg-bgl18-01a-cap08 40 99 99 0 CA
csg-bgl18-01a-cap08 60 99 99 0 CA
csg-bgl18-01a-cap08 64 99 99 0 CA
csg-bgl18-01a-cap19 149 99 99 0 CA
Conditions
issue seen intermittently while executing below show CLI's
show ap dot11 5ghz cleanair air-quality summary
show ap dot11 24ghz cleanair air-quality summary
Workaround
if show cli unable to display proper data, as specified in symptoms section
user can get proper data via Webui
Go to Monitoring -> Wireless->CleanAir Statistics
select desired radio interface 5Ghz Or 2.4Ghz
then select Air Quality Report
Further Problem Description