Symptom
A vulnerability in certain access control mechanisms for the Secure Shell (SSH) server implementation for Cisco Wireless LAN Controller (WLC) Software could allow an unauthenticated, adjacent attacker to access a CLI instance on an affected device.
The vulnerability is due to a lack of proper input- and validation-checking mechanisms for inbound SSH connections on an affected device. An attacker could exploit this vulnerability by attempting to establish an SSH connection to an affected controller. An exploit could allow the attacker to access an affected device''s CLI to potentially cause further attacks.
Please refer to the Security Advisory: https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-201904017-wlc-ssh
Conditions
This defect is only applicable up to 8.5 releases. From 8.6 and higher, SSH implementation is different, so this bug would not apply
For more information, please refer to the Security Advisory.
Workaround
Please refer to the Security Advisory.
Further Problem Description
Fixed releases:
8.3.150.0
8.5.140.0
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 5.4:
https://tools.cisco.com/security/center/cvssCalculator.x?version=3.0&vector=CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
CVE ID CVE-2019-1805 has been assigned to document this issue.
Additional information on Cisco''s security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html