Symptom
The following messages are seen in the MDS 9000 syslog:
show logging log
2018 May 2 11:31:39 switchname %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on nginx
2018 May 2 18:31:41 switchname _f worker %USER-3-SYSTEM_MSG: check_tty:could not get tty - process
2018 May 2 11:31:41 switchanme %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on nginx
2018 May 2 18:31:43 switchname _f worker %USER-3-SYSTEM_MSG: check_tty:could not get tty - process
2018 May 2 11:31:43 switchname %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on ngi
Conditions
Analytics is enabled
Workaround
Ignore the messages or configure less granular logging for VSD
logging level vshd 4
The trade-off is other level 5 informational messages will also not be displayed.
Further Problem Description
Resolution Summary
To be completed when resolved.