Symptom
A new option (role) was added to the exec mode "switch" command to allow support for the 1+1 redundancy stacking feature.
This is supported on 3850 for stackable models but of no use for "WS-C3850-48XS" stackwise(virtual) gears.
This defect is raised to remove the CLI "role" for WS-C3850-48XS,
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-48XS-E , VID: V02 , SN: FOC2035Z1ZJ
!
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 68 WS-C3850-48XS 16.6.3 CAT3K_CAA-UNIVERSALK9 BUNDLE
2 68 WS-C3850-48XS 16.6.3 CAT3K_CAA-UNIVERSALK9 BUNDLE
!
3850# switch 1 ?
priority Set the priority of the specified switch
renumber Renumber the specified switch number
role Set the new switch mode of the Switch
stack Stack port enable or disable
!
3850# switch 1 role ?
active Set the new switch to 1+1 active mode
standby Set the new switch to 1+1 standby mode