Symptom
A vulnerability in the Bash shell implementation for Cisco NX-OS Software could allow an authenticated, local attacker to bypass the limited command set of the restricted Guest Shell and execute commands at the privilege level of a network-admin user outside of the Guest Shell. The attacker must authenticate with valid administrator device credentials.
The vulnerability is due to the incorrect implementation of a CLI command that allows a Bash command to be incorrectly invoked on the Guest Shell CLI. An attacker could exploit this vulnerability by authenticating to the device and entering a crafted command at the Guest Shell prompt. A successful exploit could allow the attacker to issue commands that should be restricted by a Guest Shell account.
Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
This advisory is available at the following link:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-bash-bypass
Conditions
Please refer to the Security Advisory.
Workaround
Please refer to the Security Advisory.
Further Problem Description
Please refer to the Security Advisory.
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 5.7:
https://tools.cisco.com/security/center/cvssCalculator.x?version=3.0&vector=CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L
CVE ID CVE-2019-1730 has been assigned to document this issue.
Additional information on Cisco''s security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html