Symptom
A vulnerability in the Tetration Analytics agent for Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an authenticated, local attacker to execute arbitrary code as root.
The vulnerability is due to an incorrect permissions setting. An attacker could exploit this vulnerability by replacing valid agent files with malicious code. A successful exploit could result in the execution of code supplied by the attacker.
Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
This advisory is available at the following link:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-tetra-ace
This advisory is part of the March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication, which includes 25 Cisco Security Advisories that describe 26 vulnerabilities. For a complete list of the advisories and links to them, see Cisco Event Response: March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication.
http://tools.cisco.com/security/center/viewErp.x?alertId=ERP-70757
Conditions
Please refer to the Security Advisory.
Workaround
Please refer to the Security Advisory.
Further Problem Description
Please refer to the Security Advisory.
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 7.8:
https://tools.cisco.com/security/center/cvssCalculator.x?version=3.0&vector=CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVE ID CVE-2019-1618 has been assigned to document this issue.
Additional information on Cisco''s security vulnerability policy can be found at the following URL: