Observed that when an octane card is in slot0 with RSP4-Lite boards, Rx errors are seen incrementing continuously on the EOBC port50 of the line-card. This is shown below: sysadmin-vm:0_RSP0# show controller switch statistics location 0/LC0/LC-SW Tue Dec 12 06:35:31.447 UTC Rack Card Switch Rack Serial Number -------------------------------------- 0 LC0 LC-SW Tx Rx Phys State Tx Rx Drops/ Drops/ Connects Port State Changes Packets Packets Errors Errors To -------------------------------------------------------------------- 0 Up 0 14626 65602 0 0 NP0 1 Up 0 16 0 0 0 NP0 50 Up 0 519128 861929 0 153 RP0 >>>> Errors seen here 51 Up 0 0 0 0 0 RP1 This was observed with the above mentioned combination in both Torchwood and Samurai chassis in DT
The issue is seen only when an Octane card is present in slot-0 and RSP4-Lite is used. The errors are not seen when the octane card is present in slot-3 or with other RSP's. Also, the issue was confirmed in DT to be happening on 9906 and 9006 chassis where this combination of RSP, LC and LC-slot is present. Other combinations haven't been tried. Following is h/w and s/w build of the torchwood setup: RP/0/RSP0/CPU0:delta#show platform Tue Dec 12 12:06:33.862 IST Node Type State Config state -------------------------------------------------------------------------------- 0/RSP0/CPU0 A9K-RSP880-LT-TR(Active) IOS XR RUN NSHUT 0/RSP1/CPU0 A9K-RSP880-LT-TR(Standby) IOS XR RUN NSHUT 0/FT0 ASR-9906-FAN OPERATIONAL NSHUT 0/FT1 ASR-9906-FAN OPERATIONAL NSHUT 0/0/CPU0 A99-8X100GE-TR IOS XR RUN NSHUT 0/2/CPU0 A99-12X100GE IOS XR RUN NSHUT 0/3/CPU0 A99-8X100GE-TR IOS XR RUN NSHUT 0/FC0 A99-SFC-T OPERATIONAL NSHUT 0/FC1 A99-SFC-T OPERATIONAL NSHUT 0/FC2 A99-SFC-T OPERATIONAL NSHUT 0/FC3 A99-SFC-T OPERATIONAL NSHUT 0/FC4 A99-SFC-T OPERATIONAL NSHUT 0/PT0 A9K-AC-PEM-V3 OPERATIONAL NSHUT RP/0/RSP0/CPU0:delta#show install active summary Tue Dec 12 12:06:39.732 IST Active Packages: 7 asr9k-xr-6.4.1.26I version=6.4.1.26I [Boot image] asr9k-mpls-x64-2.0.0.0-r64126I asr9k-mpls-te-rsvp-x64-2.1.0.0-r64126I asr9k-ospf-x64-1.0.0.0-r64126I asr9k-mgbl-x64-2.0.0.0-r64126I asr9k-mcast-x64-2.0.0.0-r64126I asr9k-k9sec-x64-2.1.0.0-r64126I
No workarounds known