OPERATIONAL DEFECT DATABASE
...

...
N3K may run into issues with copied over files not fully copied due to bootflash reached capacity. No clear error messages will be seen. Example below: =================================================== N3K may run into issues with copied over files not fully copied due to bootflash reached capacity. No error messages will be seen. Example below: switch# copy ftp: bootflash: Enter source filename: nxos.7.0.3.I7.2.bin Enter vrf (If no input, current vrf 'default' is considered): management Enter hostname for the ftp server: 172.16.53.46 Enter username: user Password: /bootflash/nxos.7.0.3.I7.2.bin: short write <-- SHORT WRITE ERROR MESSAGE ***** Transfer of file Completed Successfully ***** Copy complete, now saving to disk (please wait)... switch# dir bootflash: 4096 Sep 20 19:31:24 2017 .rpmstore/ 4609 Dec 01 01:54:08 2017 20171201_015339_poap_12769_init.log 4096 Dec 23 13:28:46 2016 home/ 4096 Dec 01 02:22:24 2017 logflash/ 702663680 Sep 20 19:20:11 2017 nxos.7.0.3.I4.7.bin 882475008 Dec 01 02:19:17 2017 nxos.7.0.3.I7.1.bin 206848000 Dec 01 02:21:39 2017 nxos.7.0.3.I7.2.bin <-- FULL FILE SIZE MISSING 0 Dec 01 01:55:32 2017 platform-sdk.cmd 4096 Dec 01 01:53:39 2017 scripts/ 1024 Dec 01 01:51:57 2017 sprom_2_0_1 1024 Dec 01 01:51:57 2017 sprom_3_0_0 4096 Dec 13 19:52:28 2016 vdc_2/ 4096 Dec 13 19:52:28 2016 vdc_3/ 4096 Dec 13 19:52:28 2016 vdc_4/ 4096 Dec 22 09:17:19 2016 virtual-instance/ Usage for bootflash://sup-local 1891880960 bytes used 163840 bytes free <-- Missing space to copy file 1892044800 bytes total ======================= This results in error upon install: switch# install all nxos bootflash:nxos.7.0.3.I7.2.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive "Failed to process nxos image". Pre-upgrade check failed. Return code 0x404F0003 (SRG file not present/some modules are not supported in target image). switch %$ VDC-1 %$ %USER-0-SYSTEM_MSG: ISSU ERROR: nbi_open failed. - new_installer
Currently seen on Nexus 3048 running 7.0(3)I4(7)
Clearing space in the bootflash will assist in proceeding with upgrade
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.