Symptom
N7k with in continuous boot loop
! Output seen from the console
All gzip files are: /var/sysmgr/core_restore/0x901_aclmgr_core.6443.gz
Unzipping /var/sysmgr/core_restore/0x901_aclmgr_core.6443.gz
Moving /var/sysmgr/core_restore/0x901_aclmgr_core.6443 to /var/sysmgr/tmp_logs
All gzip files are: /var/sysmgr/core_restore/0x901_aclmgr_core.7226.gz
Unzipping /var/sysmgr/core_restore/0x901_aclmgr_core.7226.gz
Moving /var/sysmgr/core_restore/0x901_aclmgr_core.7226 to /var/sysmgr/tmp_logs
<==== at this point the Switch/Supervisor starts reloading
>>>
>>>
>>>
! Output seen from the VTY (e.g. SSH/Telnet)
Conditions
Console logs show multiple aclmgr process crash before reload.
Further Problem Description
aclmgr seems to be a victim of some other issue which causes misconfiguration/missing configuration resulting it to crash.