Following is the Last Reset timestamp seen on mini skyhammer card following a router reload : RP/0/RSP0/CPU0:delta#show platform summary location 0/1/cpu0 Wed Oct 25 14:38:21.140 IST ------------------------------------------------------------------------------- Platform Node : 0/1/CPU0 (slot 3) PID : A9K-4X100GE Card Type : ASR9K 4 port 100GE LC LAN Module VID/SN : V00 / FOC2138NX10 Oper State : IOS XR RUN Last Reset : N/A : Thu Jan 1 05:30:00 1970 UTC Configuration : Power is enabled Bootup enabled. Monitoring enabled Rommon Ver : Version 9.23 IOS SW Ver : 6.4.1.18I Main Power : Power state Enabled. Estimate power 550 Watts of power required. Faults : N/A -------------------------------------------------------------------------------
The issue is seen on mini skyhammer card i.e. A9K-4X100GE. The issue was confirmed to be seen on both RSP4L and RSP4 on 6.4.1.18I and even a private based on 6.4.1.20I with a related fix for mini skyhammer. RP/0/RSP0/CPU0:delta#show platform Wed Oct 25 14:30:36.290 IST Node Type State Config State ----------------------------------------------------------------------------- 0/RSP0/CPU0 A9K-RSP880-LT-TR(Active) IOS XR RUN PWR,NSHUT,MON 0/RSP1/CPU0 A9K-RSP880-LT-TR(Standby) IOS XR RUN PWR,NSHUT,MON 0/0/CPU0 A99-8X100GE-TR IOS XR RUN PWR,NSHUT,MON 0/1/CPU0 A9K-4X100GE IOS XR RUN PWR,NSHUT,MON 0/2/CPU0 A99-12X100GE IOS XR RUN PWR,NSHUT,MON 0/3/CPU0 A99-8X100GE-TR IOS XR RUN PWR,NSHUT,MON RP/0/RSP0/CPU0:delta#show install committed summary Wed Oct 25 14:32:10.759 IST Default Profile: SDRs: Owner Committed Packages: disk0:asr9k-mini-px-6.4.1.18I disk0:asr9k-fpd-px-6.4.1.18I disk0:asr9k-k9sec-px-6.4.1.18I disk0:asr9k-mcast-px-6.4.1.18I disk0:asr9k-mgbl-px-6.4.1.18I disk0:asr9k-mpls-px-6.4.1.18I disk0:asr9k-optic-px-6.4.1.18I
No workarounds know for this issue. However, the LC starts reporting the correct timestamp after being reloaded once.