Symptom
A crash in the SISF Main Thread or SISF Switcher Thread may be observed.
Conditions
This affects switching platforms which use the SISF (Switch Integrated Security Features) infrastructure.
To determine if SISF is active perform the command show proc | SISF, as shown in the following example:
Switch#show proc | include SISF
224 Mwe AAC1686B90 4 6 66653536/63000 0 SISF Switcher Th
225 Mwe AAC1686B90 5 26 19259888/63000 0 SISF Main Thread
Common configuration that enables SISF is:
ip dhcp snooping vlan x - y
Further Problem Description
None.
PSIRT Evaluation
The Cisco PSIRT has evaluated this issue and does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels.
If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation.
Additional information on Cisco's security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html