Symptom
FPD not ready for Fabric Cards
sysadmin-vm:1_RP1# show hw-module fpd | e CURRENT
Wed Jan 4 08:45:22.409 UTC
FPD Versions
===============
Location Card type HWver FPD device ATR Status Run Programd
-------------------------------------------------------------------------------
F0/FC2 NCS-F-FC 0.0 CCC-FPGA NOT READY 0.00 0.00
F0/FC2 NCS-F-FC 0.0 CCC-Power-On NOT READY 0.00 0.00
F0/FC2 NCS-F-FC 0.0 CRE-FPGA-DC NOT READY 0.00 0.00
F0/FC2 NCS-F-FC 0.0 CRE-FPGA-MB NOT READY 0.00 0.00
F0/FC3 NCS-F-FC 0.0 CCC-FPGA NOT READY 0.00 0.00
F0/FC3 NCS-F-FC 0.0 CCC-Power-On NOT READY 0.00 0.00
F0/FC3 NCS-F-FC 0.0 CRE-FPGA-DC NOT READY 0.00 0.00
Conditions
software upgrade or router reload
Workaround
process restart ccc_driver location
Further Problem Description
Recovery: process restart of ccc_driver for a ccc process master node for a given rack.
sysadmin-vm:0_RP0# process restart ccc_driver location 0/RP0
Mon May 1 10:46:43.944 UTC
proc-action-status User root (127.0.0.1) requested restart for process ccc_driver(0) at 0/RP0 'Sending signal 15 to process ccc_driver(IID 0) pid=4219'
sysadmin-vm:0_RP0# 0/RP0/ADMIN0:May 1 10:46:44.140 : pm[4157]: %INFRA-Process_Manager-3-PROCESS_RESTART : Process ccc_driver (IID: 0) restarted
0/RP0/ADMIN0:May 1 10:46:47.092 : wdmon[4276]: %INFRA-WDMON_LIB-3-CCC_WATCHDOG_PUNCH_ERROR : Error occurred in HW watchdog punching logic (No connection to CCC driver).