Symptom
When configuring a SPAN session in ACI, the monitor session goes into a failed state with the following:
Leaf5# show monitor session all
session 9
---------------
description : Span session 9
type : erspan
version : 2
oper version : NA
state : failed (no-oper-src-dst) <-----
erspan-id : 1
granularity :
vrf-name : jr:sb
acl-name :
ip-ttl : 64
ip-dscp : ip-dscp not specified
destination-ip : 192.168.21.10/32
origin-ip : 1.1.1.1
mode : access
source intf :
rx : Po2 Po3
tx : Po2 Po3
both : Po2 Po3
source VLANs :
rx :
tx :
both :
filter VLANs : 30,53,8
Conditions
You are using EX switches as the SPAN Source
The DST IP is learnt as an EP in the fabric in the same VRF as the SPAN SRC.
The DST Group was changed to trigger the issue