Symptom
LPTS error messages in the ASR9K router.
LC/0/3/CPU0:Jul 31 20:07:15.848 UTC: pifibm_server_lc[311]: %OS-PLATFORM_LPTS_PIFIB-3-BACKEND_EDM : pl_pifib_edm_get_fn: EDM backend function backend_edm_get failed: 'sysdb' detected the 'warning' condition 'A verifier or EDM callback function returned: 'not supported''
Conditions
Do LPTS MIB polling for A9K-SIP-700 type LC.
Workaround
The message is not service impact.
Also can just create the logging suppression rule to suppress the message:
1> logging suppress rule test alarm OS PLATFORM_LPTS_PIFIB BACKEND_EDM
In this example, create a rule named "test" that filters based on the three categories of message category, message code and group name.
2> Then apply this rule to a specified location to suppress the message:
logging suppress apply rule test source location 0/3/CPU0 ==> This is the line card where the message are from.
Further Problem Description
None