Symptom
+ Some interfaces even if in UP status show in "show controller phy" as "SFP+ is Powered Off!?
RP/0/RP0/CPU0:router#show controllers tenGigE 0/7/0/56 phy
Wed Aug 10 07:51:30.441 CDT
SFP+ General Info:
=================
PHY/SFP+ Status: SFP+ is Disabled due to low power <<<<
SFP+ is Powered Off! <<<
SFP+ Info:
=========
Max Power Dissipation: 0 mW <<<
+ That interface however is UP:
RP/0/RP0/CPU0:router#show interfaces tenGigE 0/7/0/56
Wed Aug 10 08:04:06.711 CDT
TenGigE0/7/0/56 is up, line protocol is up
Conditions
+ only affects PAT linecards
Workaround
For the power you can use the DOM command and see if you good TX/RX power.
=> n = logical slice number [0,1,2,3]
=> p = 15 port number corresponding to the slice. Specify in HEX 0-E
=> P = speed 1= 10G
[sysadminnvm:0_1:~]$ slice_driver_client_test_cli -Q -n2 -p1 -P1
cmds entered = 4, last cmd = 0, speed = 1 slices = 2
Connect Ok, now wait.....
test_cli_connect_cb for BAO Driver via CAPI.
Client connection to Slice Driver ok, hdl=0x20f5310
HDL Match!!!!
Send CAPI message for test command 20
slice = 2
received response get_optics_dom_done_cb.
get_optics_dom_done_cb: SZ 643
SFPP info:
Optics type: 1
Vendor Name: CISCO-AVAGO
Vendor OUI IEEE Company ID: 0x0000176a
Vendor Part Number: 10-2415-03
PID: SFP-10G-SR
Vendor Revision Number : G2.5
Vendor Serial Number: AGD161944PT
Vendor Date-Lot Code: 120517
CLEI Code: COUIA8NCAA
VID: V03
Laser Wave Length: 82.00nm
========================================
Temperature: 0.03°C
Vcc: 54668.00uV
Tx Bias: 2.00uA
Tx Power: 0.10uW
Rx Power: 0.10uW
========================================
ALARMS
NONE
========================================
WARNINGS
NONE
========================================
RX WARNINGS
*** Low Rx Power WARNING ***
cmd_type: 25, reply RC: 0
Disconnecting from Slice Driver
[sysadmin-vm:0_1:~]$