Symptom
sconbkup[412]: %MGBL-CONFIG-7-INTERNAL : cfgmgr_cmn_nvgen_runcfg: Spawned process (15851747) returned unsuccessful wait status (Nvgen server failed to get list of partition names from config manager. This will cause ASCII backup file not to get updated.) : pkg/bin/sconbkup : (PID=876764) : -Traceback= dae4f04 dadf285 b59d382 b59d5de 8b5853c c9d8050
RP/0/RP0/CPU0:Dec 16 12:07:40.068 : syslog_archive_logger[65796]: %OS-SYSLOG-2-ARCHIVE_THRESHOLD_CROSSED : Syslog archive threshold(100%) crossed: current: 106266923, max: 104857600
RP/0/RP0/CPU0:Dec 16 12:09:38.002 : nvgen[359]: %MGBL-NVGEN-3-PART_NAMES_GET_ERR : Could not get partitions names from cfgmgr: 'sysdb' detected the 'resource not available' condition 'Not enough memory was available to complete the operation'
RP/0/RP0/CPU0:Dec 16 12:09:39.546 : nvgen[65763]: %MGBL-NVGEN-4-CONFIG_GEN_ERR : Generation of configuration in ASCII format failed due to internal error. The file '/tmp/router.cfg.tmp' was not updated
Conditions
Unable to commit new configuration or reload the system without a force operation