Symptom
NV sat interface reports CFM local fault (RDI bit set in outgoing CCMs) satellite host switchover.
Conditions
The user is running a CFM Satellite dual head topology with 'mep auto-crosscheck' configuration on the standby host.
Workaround
To avoid this issue, do not configure the NV sat port MEP ID in crosscheck and do not use auto crosscheck.
Further Problem Description
Upon host switchover, the 'going active' old standby host receives a packet from the old active node, causing the new active to create a crosscheck MEP with its own MEP ID. After the switchover completes, this new auto-crosscheck MEP times out & the RDI bit is set in outgoing CCMs.
The state can be cleared with 'clear ethernet cfm peer meps all' on the new active node.