The following output (sample) is a representation of the incorrect messaging that will occur if the RP2 CPLD is not upgraded. The only FRU that actually requires upgrade when moved to ASR1009-X or 1006-X is the RP2. All log and "show platform" state messages are irrelevant except for RP2 and when upgraded, all other FRU messaging should clear to correct output. Router#sh plat Chassis type: ASR1006-X Slot Type State Insert time (ago) --------- ------------------- --------------------- ----------------- 0 ASR1000-SIP40 act_rp_cpld_incompatib00:07:53 R0 ASR1000-RP2 act_rp_cpld_incompatib00:07:53 R1 ASR1000-RP2 act_rp_cpld_incompatib00:03:58 F0 ASR1000-ESP40 act_rp_cpld_incompatib00:07:53 P0 Unknown ps, fail never P1 Unknown ps, fail never P2 Unknown ps, fail never snip-- Slot CPLD Version Firmware Version --------- ------------------- --------------------------------------- 0 N/A N/A 1 N/A N/A R0 08103002 15.4(2r)S R1 10021901 15.2(1r)S F0 N/A N/A F1 N/A N/A *Jul 2 19:35:09.210: %CMRP-3-FRU_CPLD_INCOMPATIBLE: R0/0: cmand: ASR1000-ESP40 in slot F1 has been held in reset as its CPLD firmware version is incompatible with ASR1006-X *Jul 2 19:37:01.896: %CMRP-3-FRU_CPLD_INCOMPATIBLE: R0/0: cmand: ASR1000-SIP40 in slot 0 has been held in reset as its CPLD firmware version is incompatible with ASR1006-X *Jul 2 19:37:12.731: %IOSXE_OIR-6-ONLINECARD: Card (rp) online in slot R1 *Jul 2 19:37:12.738: %CMRP-3-FRU_CPLD_INCOMPATIBLE: R0/0: cmand: ASR1000-RP2 in slot R1 has been held in reset as its CPLD firmware version is incompatible with ASR1006-X *Jul 2 19:37:12.951: %IOSXE_OIR-6-OFFLINECARD: Card (rp) offline in slot R1 *Jul 2 19:35:36.440: %CMRP_PFU-4-PWR_MGMT_WARN: R0/0: cmand: WARNING: Insufficient number of power supplies (0) is installed for power redundancy mode none. The system needs 1057 watts additional power.
The failure is specific to customer environments where an existing RP2 which has not been upgraded to the latest CPLD to support the asr1009-x or 1006-x. If the customer installs said RP2(s) into these chassis types the symptoms indicated will occur. The new chassis will come with upgraded RP2's if ordered as part of a bundle
None. CPLD must be upgraded