General
Symptom:
LLDP PDU could get discarded at neighboring switch/host behind FEX HIF port.
leaf1(config)# show lldp interface Ethernet 7/25
Interface Information:
Enable (tx/rx/dcbx): Y/Y/Y Port Mac address: 3c:0e:23:c5:da:a4
Peer's LLDP TLVs:
Type Length Value
---- ------ -----
001 007 0410bd18 18fcca
002 011 07457468 3130312f 312f39
003 002 0078
004 015 45746865 726e6574 3130312f 312f39
005 006 73776974 6368
006 155 43697363 6f204e58 2d4f5328 746d2920 6e373730 302c2053 6f667477
61726520 286e3737 30302d73 322d646b 39292c20 56657273 696f6e20
362e3228 3134292c 2052454c 45415345 20534f46 54574152 4520436f
70797269 67687420 28632920 32303032 2d323031 33206279 20436973
636f2053 79737465 6d732c20 496e632e 20436f6d 70696c65 6420372f
32372f32 30313520 393a3030 3a3030
007 004 00140004
008 014 070610bd 1818fcca 02050000 0000
127 005 00014201 01 >>>>>>>>>>>> no end PDU tlv
leaf1(config)#
Conditions:
LLDP PDU sent from FEX CPU
Further Problem Description
Issue is only present in 6.2.x.
Issue is fixed in 7.3(0)D1(1) and 7.2.x.