General
This release notes can be used to investigate booting issue on the NIM T1/E1 cards.
Symptom
The Fortitude T1/E1 modules will fail to boot up with a booting message. These modules can be used in both voice and data mode, and both use cases are affected since the module simply does not boot up.
For example:
%SPA_OIR-3-RECOVERY_RELOAD: subslot 0/1: Attempting recovery by reloading SPA
%SPA_OIR-6-OFFLINECARD: SPA (NIM-2MFT-T1/E1) offline in subslot 0/1
%SPA_OIR-3-EVENT_TIMEOUT: subslot 0/1: Timeout waiting for SPA OIR event
-Traceback= 1#08b65be3f4ae1c460ee5571211270cd0 :7F307787C000+B197083 :7F307787C000+B16FA70 :7F307787C000+8FE7A17
Conditions
Loading the any of the modules below:
NIM-1MFT-T1/E1
NIM-2MFT-T1/E1
NIM-4MFT-T1/E1
NIM-8MFT-T1/E1
NIM-1CE1T1-PRI
NIM-2CE1T1-PRI
NIM-8CE1T1-PRI
Workaround
Please open a case with TAC to get the modules working again. A RMA is not needed for modules that cannot boot due to this defect.
Further Problem Description