Symptom
After kron performs a write of the startup-config (e.g. 'write mem'), it is locked indefinitely (i.e., the startup-config and running-config are unavailable):
switch# show run
Unable to get configuration. Try again later.
Conditions
kron is not returning control of nvram after performing a write of the configuration. This occurs on a Sup7E running 15.0(01)XO.
Workaround
Reload the switch.
To avoid this condition, use EEM with the timer event to schedule the required task.
Further Problem Description