BugZero found this defect 520 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
12/31/2022
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.9.x
v12.9 Update 1
If your Firebox is configured in Bridge Mode with a static IP on the interface, the HTTPS connection handled by the HTTPS Proxy fails in Fireware v12.9. When this occurs, you see the proxy error "failed with Network is unreachable (5 tries left)".Example log message: Dec 30 18:23:50 2022 SSLMgt16_Bridge_Security_Suite local3.err pxy[3040]: 0x33adaa00-1249 pxy_connect_tcp: conn 1249 fd 43 B connect from [10.0.1.3]:62715 to [192.0.2.1]:443 failed with Network is unreachable (5 tries left)
Change the Firebox interface configuration from Static IP to DHCP and configure the DHCP server to assign a static IP to the Firebox.