Updating vCenter fails with the below error:var/log/vmware/applmgmt/update_microservice.log2021-12-15 08:39:46,930 - 9844 - update_microservice:: _runEvent: 395 - ERROR - Event callback failed: UnboundLocalError("local variable 'taskFailStatus' referenced before assignment") 'Traceback (most recent call last):\n File "/usr/lib/applmgmt/update/py/vmware/appliance/update/update_b2b.py", line 2600, in install\n MAX_RESUME_THRESHOLD)\n File "/usr/lib/applmgmt/update/py/vmware/appliance/update/update_b2b.py", line 2904, in _is_resume_threshold_reached\n if resume_count and int(resume_count) >= resume_threshold:\nValueError: invalid literal for int() with base 10: \'resume-threshold\'\n\nDuring handling of the above exception, another exception occurred:\n\nTraceback (most recent call last):\n File "/usr/lib/applmgmt/update/py/vmware/appliance/update/update_microservice.py", line 388, in _runEvent\n coroutine.send(1)\n File "/usr/lib/applmgmt/update/py/vmware/appliance/update/update_microservice.py", line 241, in stageAndInstallEventHandler\n coroutine.send(i)\n File "/usr/lib/applmgmt/update/py/vmware/appliance/update/update_b2b.py", line 2695, in install\n task.update(taskFailStatus, task.progress.completed,\nUnboundLocalError: local variable \'taskFailStatus\' referenced before assignment\n'
The value for resume-count in the config table in DB gets updated with the string "resume-threshold" instead of an integer value.
Currently there is no resolution.
To workaround the issue:Try to unstage and retry stage-install.OR Take a snapshot/backup of the vCenter appliance.Run the following commands on the VCSA via an SSH session: service-control --stop applmgmt rm -rf /storage/core/software-update/updates/*rm -rf /storage/core/software-update/stage/*rm -rf /storage/db/patching.dbmv /storage/core/software-packages/staged-configuration.json /storage/coremv /etc/applmgmt/appliance/software_update_state.conf /storage/core service-control --start applmgmt Retry the update.
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.