A "FW in FAULT state" message is displayed in Linux driver logs during the controller firmware update flash following an online HPE MR Gen10 Plus and Gen11 storage controller firmware update.During an online firmware update, the Linux driver logs may display a message indicating a firmware fault, "Firmware in FAULT state." This message appears across all supported Linux operating systems after the firmware update completes successfully.
This issue applies to the following HPE MR Gen10 Plus and Gen11 storage controllers:HPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller (P58335-B21)HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller (P47781-B21)HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller (P47789-B21)HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller (P47777-B21)HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller (P47785-B21)HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P26279-B21)HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P06367-B21)HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26325-B21)HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26324-B21)
This log message is not associated with any loss of controller functionality, and no corrective action is required from the host or system administrators.The firmware flash progress and completion can be verified through iLO IML logs.Example:Firmware flashed (Success: Device in slot 2: active fw [REDACTED], pending fw [N/A])Firmware flashed (Firmware Package - HPE MR408i-p Gen11 Tri Mode Controller [REDACTED])The "FW in FAULT state" message observed in the Linux driver logs is a normal part of the firmware–host driver handshake mechanism during an online firmware update, and it does not indicate a fault or issue affecting system operation.Since this message can occur in various scenarios, and the host driver cannot distinguish between a true fault and a normal update process based solely on this message, the message cannot be selectively suppressed. The firmware update completes successfully, and no reboot or corrective measures are necessary.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.