When upgrading NativeEdge from version 3.2.0.0 or 4.0.0.0 to 4.1.0.0, the upgrade process fails during the virtual machine shutdown phase. Error messages observed: Destination node failed to setup necessary resources defined in the request: rpc error: code = Unknown desc = failed to create network interfaces for live migration: sql: no rows in result set Or in the user interface: Error in migrating the virtual machine: invalid body inputs: segment bridge1 is not found in machine hardware data
The bridged network segment name was modified after the virtual machine was deployed. During migration, the destination node expects the original segment name, causing a mismatch and failure to create network interfaces.
Workaround for versions 3.2.0.0 and 4.0.0.0: Do not change bridged segment names after deploying virtual machines.If already changed, revert the segment name to its original value before migration.Alternatively, upgrade nodes individually instead of performing a cluster-wide upgrade Permanent Fix: NativeEdge version 4.1.0.0 includes logic to update virtual machine configuration when segment names change.Upgrade from 4.1.0.0 to later NativeEdge releases to avoid this issue.