OPERATIONAL DEFECT DATABASE
...


...

At NativeEdge v4.0.0.0, the Dell Automation Platform orchestrator displays a daily critical alert for a security setup change. The error message is: There has been a modification to the security setup of Endpoint xxxx. In the failure reason, notice that the test-name that reports the issue is: check-timesync-state.sh. This check validates that if the endpoint time is synced with the orchestrator.
ece-agent.log was rotated and the check-timesync-state.sh unable to retrieve time sync log from the log files. Then fall into the backup checking method - using chronyc sources. Since the time is properly synced, so the chrony daemon is not running, this causes the `chronyc source` command failure then trigger the critical alert to the orchestrator.
This critical alert is a false positive alert. Users can safely ignore this alert in the system. In the next available NativeEdge release, this alert is removed.