NMDA / SAP IQ backup is configured following documentation. Issue seen with: Networker Server Red hat server 7.8 Networker 19.3 Networker NMDA 19.3 SAP Sybase IQ 16.1 Networker Client 19.3 Errors seen in log following failure: 170519:nsrdasv: Received an error from the server ''. Error code: 13720. Severity: 21. State: 0. SQL Anywhere Error -697: Error during backup/restore: The _syb_open function failed.169604:nsrdasv: Unable to back up the database 'd2dwtest'. 170484:nsrdasv: The backup was unsuccessful. The libnsriqbr and savegrp log files provide details. 170548:nsrdasv: The child nsrdasv program exited with a non-zero return code: 65280
SAP IQ User Group does not have correct user permissions defined.
Make sure that user=sybaseuser,host=clientname.fqdn.com is defined, see example screenshot:
Click on a version to see all relevant bugs