Symptom
Supervisors information for N77K are showing different ?RAID data from CMOS?.
fcr01a.wdc07# show module
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
9 0 Supervisor Module-2 N77-SUP2E active *
10 0 Supervisor Module-2 N77-SUP2E ha-standby
Mod Sw Hw
--- --------------- ------
9 8.2(7a) 1.4
10 8.2(7a) 1.4
fcr01a.wdc07# show system internal raid
RAID data from CMOS = 0xfa 0xff <<<<<
RAID data from driver disks 0 bad 0 name
Current RAID status info:
Bootflash: /dev/sda
Mirrorflash:
fcr01a.wdc07# attach module 10
fcr01a.wdc07(standby)# show system internal raid
Current RAID status info:
RAID data from CMOS = 0xf7 0x6f <<<<
RAID data from driver disks 0 bad 0 name
Bootflash: /dev/sda
/bin/cat: /var/log/boot_node_mirror: No such file or directory
Conditions
Nexus 7700 Sup2E supervisor
Workaround
None. The behavior is expected as RAID is not used for N7700 Sup2E.
Further Problem Description
Potential RAID issue.
PSIRT Evaluation:
The Cisco PSIRT has evaluated this issue and determined it does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels.
If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation.
Additional information on Cisco's security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html