Symptom
CISCO-ENHANCED-MEMPOOL-MIB does not work on c9200 16.9.2 even when MIB is loaded on the device
I checked and I could see that CISCO-ENHANCED-MEMPOOL-MIB is not completely working while CISCO-MEMORY-POOL-MIB works.
When any OID from CISCO-ENHANCED-MEMPOOL-MIB is being pulled
Polling not working for OID 1.3.6.1.4.1.9.9.221.1.1.1.2
[root@pi-38-pro ~]# snmpwalk -v2c -c stevencom 10.62.149.141 1.3.6.1.4.1.9.9.221.1.1.1.2
SNMPv2-SMI::enterprises.9.9.221.1.1.1.2 = No Such Object available on this agent at this OID
[root@pi-38-pro ~]# snmpwalk -v2c -c stevencom 10.62.149.141 1.3.6.1.4.1.9.9.221.1.1.1.1.7
SNMPv2-SMI::enterprises.9.9.221.1.1.1.1.7 = No Such Instance currently exists at this OID
[root@pi-38-pro ~]#
[root@pi-38-pro ~]# snmpwalk -v2c -c stevencom 10.62.149.141 1.3.6.1.4.1.9.9.221.1.1.1.1.18
SNMPv2-SMI::enterprises.9.9.221.1.1.1.1.18 = No Such Instance currently exists at this OID
Conditions
Platform: Catalyst L3 Switch C9200L-48P-4X-E
Version: [Fuji], 16.09.02
Workaround
Suggest the CU to use OIDs from CISCO-MEMORY-POOL-MIB
Further Problem Description