The cloudexpress is not getting enabled or not selecting the exit interface showing LOSS as 100 and Latency 0 as below. SDWP0003100089JKT-ID01STLSDE01#show sdwan cloudexpress applications cloudexpress applications vpn 1 office365 exit-type none latency 0 loss 0 cloudexpress applications vpn 1 dropbox exit-type local interface GigabitEthernet0/0/0 latency 15 loss 2 cloudexpress applications vpn 2 office365 exit-type none latency 0 loss 0 cloudexpress applications vpn 2 dropbox exit-type local interface GigabitEthernet0/0/0 latency 15 loss 2 SDWP0003100089JKT-ID01STLSDE01#show sdwan cloudexpress local-exits VPN APPLICATION INTERFACE LATENCY LOSS ---------------------------------------------------------------------- 1 office365 GigabitEthernet0/0/0 0 100 1 office365 GigabitEthernet0/0/3.2 0 100 1 dropbox GigabitEthernet0/0/0 15 2 1 dropbox GigabitEthernet0/0/3.2 0 0 2 office365 GigabitEthernet0/0/0 0 100 2 office365 GigabitEthernet0/0/3.2 0 100 2 dropbox GigabitEthernet0/0/0 15 2 2 dropbox GigabitEthernet0/0/3.2 0 0
The Issue is seen on Cedge only running on code 17.03.03 with Office365 application, rest other application working fine.
Set up routes for the dns servers so that they always can be resolved.
Cloudexpress is not getting enabled for Office365