Symptoms
On MPA OIR ( cases soft OIR insert/remove, soft OIR reload, Hard OIR insert/remove) 1) VIC process restarts. Sample syslog: LC/0/0/CPU0:Dec 14 18:27:44.600 : sysmgr[89]: vic_0(1) (jid 353) (pid 454777) (fail_count 1) abnormally terminated, restart scheduled 2) Traffic drops due to reason RSV_DROP_IN_L3_NOT_MYMAC RP/0/RSP0/CPU0:vkg2#show controller np counters all loc 0/0/cpu0 Node: 0/0/CPU0: ---------------------------------------------------------------- Show global stats counters for NP0, revision v2 Read 17 non-zero NP counters: Offset Counter FrameValue Rate (pps) ------------------------------------------------------------------------------- 16 MDF_TX_LC_CPU 1861783 937 18 MDF_TX_FABRIC 33 0 20 PARSE_FAB_RECEIVE_CNT 33 0 21 PARSE_INTR_RECEIVE_CNT 23842 12 22 PARSE_INJ_RECEIVE_CNT 33 0 23 PARSE_ENET_RECEIVE_CNT 230744253 116088 24 PARSE_TM_LOOP_RECEIVE_CNT 9745 5 165 PRS_HEALTH_MON 3268 2 174 INTR_FRAME_TYPE_7 23842 12 205 PARSE_RSP_INJ_DIAGS_CNT 33 0 218 PARSE_LC_INJ_DIAGS_CNT 33 0 344 DBG_RSV_EP_L_RSV_ING_PUNT 1861817 937 452 RSV_DROP_IN_L3_NOT_MYMAC 228906363 115163 <------- 706 ARP 1837911 925 720 DIAGS 33 0 832 PUNT_STATISTICS 23842 12 834 PUNT_DIAGS_RSP_ACT 33 0
Conditions:
This behavior is observed which MPA is OIRed consecutively without waiting enough time.
Workaround:
Recommendation is to wait for 2 minutes before doing next MPA OIR.
Recovery:
Incase any functionality issue (such as traffic drops) is observed, it is recommended to do a MPA reload as follows: hw-module subslot reload
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.